Overlapping navy, orange and light-coloured flame-retardant fabric swatches, with a visible black anti-static grid on the orange fabric

J-HV-AS-P-R 3003001 FR 3 LAYER OPT.B

Multi-Norm Flame Retardant Hardshell Fabric with Visible Anti-Static Grid

A three-layer flame-retardant hardshell fabric featuring a visible anti-static grid, a polyester/carbon outer shell, a protective membrane and a modacrylic/cotton inner layer, developed for multi-norm protective outerwear.

Composition
Shell: 98% polyester, 2% carbon; Inner layer: 60% modacrylic, 40% cotton
Weight
330 gsm (±5%)
Usable Width
56/57 inches
Construction
Rib
Treatment
WR-FR BR membrane-FR knit
  • Visible Anti-Static Grid
  • Three-Layer Protective Hardshell
  • Multi-Norm Flame Retardant Performance
  • Tested Electric Arc Protection
  • Water-Resistant Protective Outerwear Fabric
WhatsApp JOY

Overview

Designed for protective outerwear used in demanding industrial environments, this three-layer hardshell fabric combines a flame-retardant outer shell with a visible anti-static grid, a membrane layer and a flame-retardant knitted backing. Its construction brings together protection against thermal hazards, electric arc exposure and wet conditions within a single fabric system.

The polyester/carbon outer shell and modacrylic/cotton inner layer provide a defined material structure for buyers evaluating multi-norm protective garments. Performance has been assessed through a range of fabric-level tests, with suitability for finished garments depending on garment design, construction and applicable certification requirements.

Performance & Standards

This three-layer protective fabric has been evaluated for flame resistance, thermal hazards, electric arc exposure, electrostatic properties, limited liquid chemical protection and wet-weather performance. Selected fabric-level test results are summarised below.

Key Test Results

Standard Performance Area Reported Result
EN ISO 11612:2015 Heat and flame protection A1+A2, B1, C1, E1, F1
EN ISO 11611:2015 Welding and allied processes A1+A2; radiant heat Class 1; molten metal splash Class 1
IEC 61482-2:2018 / EN 61482-1-2:2014 Electric arc box test APC 1 (Class 1)
IEC 61482-1-1:2019 Electric arc rating ATPV 9.3 cal/cm²; ELIM 8.5 cal/cm²
EN 1149-5:2018 Electrostatic properties Charge decay half-time t50 < 0.01 s; shielding factor S = 0.85
EN ISO 14116:2015 Limited flame spread, inner surface Index 3
EN 13034:2005+A1:2009 Limited liquid chemical protection Index 3 for the listed chemical tests: 30% sulfuric acid, 10% sodium hydroxide, o-xylene and 1-butanol
EN 343:2019 Resistance to water penetration Class 4; > 20,000 Pa, including after 15 washing cycles and specified mechanical conditioning
EN 343:2019 Water vapour resistance Class 3; Ret = 17.35 m²·Pa/W
EN ISO 20471:2013 High-visibility colour performance Reported pass results for tested HV yellow and HV orange samples
RIS-3279-TOM:2016 Railway high-visibility orange Reported pass result for tested HV orange sample

Testing Notes

Results are drawn from the supplier’s technical specification dated 5 May 2025, incorporating third-party laboratory and internal testing. Many reported tests used 15 washing cycles as pretreatment; conditions vary by method. Results apply to tested materials and colours, not automatically to every colourway or finished garment. Garment-level compliance and certification require separate assessment.

Applications

Potential Applications

This three-layer fabric may be considered for protective outerwear designed for industrial workplaces where flame resistance, electrostatic properties and protection against wet conditions are important selection requirements.

Potential applications include:

  • Flame-retardant protective jackets and outerwear for industrial maintenance, utilities and other workplaces involving thermal hazards.
  • Multi-norm protective rainwear for workers requiring a combination of flame-retardant performance and protection against wet weather.
  • Protective outer layers for electrical and utility workwear where fabric-level electric arc performance is relevant to garment selection.
  • High-visibility protective outerwear using suitable tested colourways, subject to the visibility requirements of the intended garment design.

Material Selection Considerations

The suitability of this fabric should be evaluated against the hazards, performance requirements and construction details of the intended garment.

  • Hazard assessment: Identify the specific thermal, electrical, electrostatic, chemical splash and weather-related hazards before selecting a fabric.
  • Garment construction: Seams, closures, linings, trims and other components may affect the performance of the finished protective garment.
  • Colour selection: High-visibility test results relate to specified tested colours and should not be assumed to apply to every available colourway.
  • Layering and comfort: Consider garment design, intended activity, environmental conditions and the effect of additional clothing layers on wearer comfort and protection.
  • Testing and compliance: Confirm the applicable requirements for the finished garment. Fabric-level test results do not constitute garment certification.

For specific end-use requirements, buyers are encouraged to review the relevant technical data and discuss material selection with JOY P&D before finalising garment development.

Take the Next Step with This Fabric

Request a fabric sample or technical documentation to support your material evaluation.

Evaluate the Fabric

Request a sample to assess the fabric for your project.

Review Technical Details

Ask for available technical specifications and documentation.